NAVIGATION: Motion profile > Synchronized movement > Electronic_gearing > Status and control word

Status and control word

Control word for electronic gearing

P 1318 MPRO_ECAM_ControlWord.

Bit number Function iPLC function
0-7 Start segment (8-bit value) -
8-15 Reserve -
16 Absolute (true) / relative (false) master relationship -
17 Absolute (true) / relative (false) master (CAM) relationship at cam in -
18 Absolute (true) / relative (false) slave (CAM) relationship at cam in -
19-23 Reserve -
24 Change gear ratio of the electronic gear online MCB_GearRatioChange
25 Disable master calculation MCB_Cam_MasterEnable
26 Enable master calculation MCB_Cam_MasterEnable
27 Select CAM table MCB_CamTableSelect
28 Start Ecam MCB_CamIn
29 Stop Ecam MCB_CamOut
30 Start Egear MCB_GearIn
31 Stop Egear MCB_GearOut

Tabelle: Control word ECAM



Status word for electronic gearing

P 1326 MPRO_ECAM_StatusWord

Bit number Description
0-7 Actual segment (8-bit value)
8-11

Actual ECAM / EGEAR state machine state (4-bit value)

0: ECAM / EGEAR asynchronous

1: ECAM / EGEAR synchronous

2: ECAM / EGEAR synchronizing

3: ECAM / EGEAR desynchronizing

4: ECAM / EGEAR active and waiting for going asynchronous

5: ECAM / EGEAR inactive and waiting for going synchronous

12-26 Reserve
27 ECAM / EGEAR is active
28 Valid segments chosen
29 Master data are valid
30 Master is initialized
31 Master calculation is active

Tabelle: Status word ECAM